Background
An Italian manufacturer of industrial control cabinets and telecom enclosures was failing EMC compliance on a new product line. The seals on the cabinet doors were letting radiated emissions escape at the seams, and the standard foam gaskets on the market degraded after repeated door cycles.
The company needed a conductive sealing material that could be cut to length on its own line, compress repeatedly without permanent set, and remain effective across a wide temperature range.
Why knitted copper mesh
Knitted wire mesh works as an EMI gasket because the interlocking loops create hundreds of independent contact points along the seam. When the door closes, the loops compress and form a continuous conductive path that absorbs and reflects radiated energy. Unlike foil or fabric-over-foam tapes, the knitted structure keeps its springback after thousands of compression cycles, and copper gives the highest conductivity per unit cost among common gasket materials.
Delivered specification
| Product | Specification |
|---|---|
| Copper knitted mesh | Width 2.5–60 cm, custom slitting, roll length 1–30 m |
| Shielding tape | SS304 / SS316 knitted mesh tape, 25 mm width |
| Colour | Natural copper yellow, customised on request |
| Wire diameter | Made to drawing |
| Certification | ISO 9001:2015 |
| Sample | Free sample coils for EMC bench testing |
| Supply ability | Up to 5,000 pieces per day |
| Delivery | About 7–10 days after payment |
How the project ran
- Free samples first. Two copper mesh widths and a 25 mm stainless shielding tape were air-freighted so the customer's EMC lab could test attenuation before any commercial commitment.
- Width tuning. After bench tests the customer settled on a 30 mm copper mesh strip for the door seam and 25 mm tape for internal cable routing.
- Pilot batch. A first production run of 500 pieces was delivered in the standard wooden case packing, with a plastic inner bag to keep the copper bright during sea freight.
- Volume release. The customer moved to monthly releases once the pilot batch passed assembly-line trial and re-testing.
Results reported by the customer
- Radiated emission readings at the door seam came back inside the CISPR limit with margin, so the product line was released for the European market.
- Compression set after repeated door cycling stayed low enough that the seal did not need replacement during the trial period.
- Because the tape is cut to length on the customer's own line, the company removed a pre-cut gasket part number from its bill of materials and simplified procurement.
Takeaway
EMI gasket projects usually fail at the sample stage, not at volume. Testing two or three mesh widths on the real cabinet before fixing the drawing is cheap; discovering a leakage problem after tooling is not. Free samples and short slitting lead times make that iteration practical.
![]()